Research reference only. Not medical advice. Most compounds are not FDA-approved. These are research chemicals, not for human consumption. Consult a qualified clinician.Read methodology Terms update on 18 Dec 2026

Combinations to avoid

Combinations flagged to avoid

Pairings the interaction engine flags because the compounds duplicate one target, push the same hormone axis twice, or carry a documented hazard together. Each page states the mechanism behind the flag and the source it rests on.

All 11 flagged combinations 11

  • GH secretagogues combined with exogenous HGHRisk: Moderate-High

    Negative feedback via somatostatin/IGF-1; risk of pituitary suppression; diminishing returns on GH output

  • GLP-1 agonist + insulin or sulfonylureasRisk: High

    Hypoglycemia risk: GLP-1 enhances glucose-dependent insulin secretion; stacking with exogenous insulin or secretagogues can drive severe lows

  • Melanotan II combined with novel peptides during dose-findingRisk: High

    Masks individual peptide response (pigmentation, nausea, BP overlap); MC1R activation raises melanoma/mole darkening concerns when dose-finding other compounds

  • Semaglutide + Liraglutide combinedRisk: Moderate

    Redundant GLP-1 receptor activation: both molecules occupy the same target with no published combination-therapy precedent.

  • Semaglutide + Tirzepatide combinedRisk: High

    Overlapping GLP-1 pathway: stacks side effects (GI, pancreatitis) with no added efficacy; FDA-flagged as unsafe combination

  • Two GHRHs in the same regimenRisk: Moderate

    Same receptor: competition at pituitary GHRH receptor; no additive benefit, reduced efficiency

  • Two GHRPs in the same regimenRisk: Moderate

    Ghrelin receptor (GHS-R1a) saturation + accelerated desensitization; may blunt long-term GH response

  • Two GIP agonists in the same regimenRisk: High

    Overlapping GIP receptor activation on the same incretin pathway: stacks GI side effects, pancreatitis signal, and gallbladder risk with no added efficacy.

  • Two glucagon-receptor agonists in the same regimenRisk: High

    Overlapping glucagon-receptor activation drives hepatic glucose output, hepatic lipid mobilization, and resting heart rate; stacking compounds metabolic and cardiovascular load with no clinical precedent

  • Two IGF-1 analogs in the same regimenRisk: Moderate-High

    Multiple IGF-1 analogs compete for the same IGF-1R pool; the second analog does not raise peak receptor activation but stacks hypoglycemia exposure, cardiac/renal/hepatic hypertrophy signal, and peripheral neuropathy risk in heavy stacks

  • Two MC1R agonists in the same regimenRisk: Moderate-High

    Overlapping MC1R activation compounds melanogenesis, mole darkening, and the documented atypical-nevus / melanoma signal seen with chronic melanocortin exposure; the safety signal scales with cumulative MC1R activation